What was permitted
This permit is for the new construction of a one-story single-family residence (SFR) at 2204 Alexander Ave, Building 2. Significant revisions have been made to the original design, including an enclosed dining room for Unit 1 and a revised floor plan for Unit 2.
The project, issued on October 12, 2026, also introduces a shared accessory room between the units and adjusts the building footprint and envelope. A R Lucas Construction LLC is the General Contractor for this active permit.
Plan a similar project
Want work like this done at your place?
Tell us what you have in mind. We scope it, price it against work like this, and lines up the right contractor. You approve; we handle the back-and-forth.
View the official permit record
Tracking number, work description, cost and dates
View the official permit record
Tracking number, work description, cost and dates
| Tracking number | 2025-137956 BP |
|---|---|
| Work permit # | — |
| Job filing number | — |
| Work type | Building Permit · New |
| Status | Active |
| Job description | BUILDING 2 1 STORY SFR 2/1 REAR OF MAIN HOUSE Revision: Permit Revision Narrative: This resubmittal documents three major revisions to the approved permit drawings for this residential development. 1. Conditioned Square Footage Unit 1: The total conditioned square footage for Unit 1 increased to include an enclosed dining room. The screened porch from the previous design is no longer part of the project scope. There are no other permit relevant revisions to Unit 1. Unit 2: The floor plan layout of Unit 2 has been revised. Floor plan on A1.2 show updated visitable route and bathroom smoke/carbon monoxide detector locations attic access and call out square footage and ceiling heights by space. Escape and rescue openings are called out in the window and door schedules on sheet A1.3. Shared Accessory Room: Introduced a new shared accessory room between Unit 1 & Unit 2. Updated FAR calculations are provided on A0.1. 2. Building Footprint & Envelope The proposed revision required minor adjustments to the building footprint & foundation. As part of the revised design the footprint of the wood deck also adjusted. Updated impervious cover and total building coverage calculations are provided on A0.1. Revisions to openings and new openings are shown in the updated window and door schedules on sheet A1.3. 3. Fire Separation Between Dwelling Units The revised design locates a shared accessory room per 2024 IRC R302.3.6 between Unit 1 and Unit 2. The function of the shared accessory room is to provide a storage space accessible from both units. The walls between the shared accessory room and dwelling units are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation and separation requirements are vertically continuous from foundation to roof deck. Structures supporting the ceiling of the shared accessory room are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation. There is no habitable space above or below the shared accessory room. All openings in walls separating dwelling units from the shared accessory room are compliant with R302.3.6.1 Opening Protection. All duct penetrations shall comply with R302.3.6.2 and shall not have openings into the shared accessory room. All other penetrations shall comply with R302.3.6.3. See A0.2 Fire Separation & Details for updated code compliance diagrams. |
| Floor / unit | — |
| Estimated cost | Not reported |
| Approved | July 11, 2025 |
| Issued | October 12, 2026 |
| Expires | April 11, 2027 |
| BBL | — |
| BIN | — |
Related searches