What was permitted
This electrical permit addresses needed upgrades for a recently purchased older home at 604 E 49th Street, focusing on adding receptacle outlets to the bathroom and living room. The bathroom work is designed to preserve existing tile by surface-mounting receptacles inside cabinets.
The project, issued on September 3, 2026, has an estimated cost of $1,500 and is being performed by OK Electric. It includes adding two new GFCI-protected circuits for the bathroom and one AFCI-protected circuit for the living room, utilizing surface-mounted conduit for a clean installation.
Plan a similar project
Want work like this done at your place?
Tell us what you have in mind. We scope it, price it against work like this in Hyde park, and lines up the right contractor. You approve; we handle the back-and-forth.
View the official permit record
Tracking number, work description, cost and dates
View the official permit record
Tracking number, work description, cost and dates
| Tracking number | 2026-114192 EP |
|---|---|
| Work permit # | — |
| Job filing number | — |
| Work type | Electrical Permit · Repair |
| Status | Active |
| Job description | This permit will cover: Bathroom circuits Living room receptacles Bathroom Circuits Recently purchased older residence; existing bathroom has no receptacle outlets. Bathroom walls have original tile the homeowner wants to preserve. Receptacles will be surface mounted inside the cabinets flanking the sink to avoid cutting into the tile meeting the 3 ft basin-proximity requirement. Adds 2 new 20A 120V GFCI breaker-protected circuits for bathroom receptacles run through a 1 EMT raceway from the exterior main panel to an accessible attic J-box allowing easier future circuit additions. This raceway also carries the living room circuit below. Installation: Install 1 raceway from panel to a centrally located 8x8x6 J-box in accessible attic space. From there pipe to a 4-square J-box above the bathroom then into the upper cabinets on either side of the sink. Install surface-mount quad receptacles with industrial covers inside the cabinets. Living Room Receptacles Adds a 20A 120V AFCI-protected circuit for in-wall receptacles in the living room located behind a future bookshelf. Shares the 1 EMT raceway from panel to the 8x8x6 J-box branching separately from that point. Installation: From the 8x8x6 J-box pipe to a new 4-square box above the bookshelf location then down to the receptacle locations. Wire size: All three circuits supplied with #10 THWN-2 sized for high attic temperatures and conductor-count adjustments. All raceways installed per code; terminations torqued per manufacturer specifications. |
| Floor / unit | — |
| Estimated cost | $1,500 |
| Approved | August 31, 2026 |
| Issued | September 3, 2026 |
| Expires | March 2, 2027 |
| BBL | — |
| BIN | — |